aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ½º¸¶Æ® ±â±â: no
- ÃøÁ¤ À¯Çü: K
- ÄÉÀÌºí ±æÀÌ: 1M
- À¯Çü: K
- ÀÌ·Ð: ¿Âµµ Á¶Àý±â
- »ç¿ë¹ý: Industrial
- ¸ðµ¨ ¹øÈ£: SHT2000 Temperature Controller
- ÃÖ´ë ÃøÁ¤ ¿Âµµ: 100 ¡Æ 119 ¡Æ
- ´ëÇü È°ÀÚ: DIGITAL
- Èû À¯Çü: ÃæÀü±â
- µð½ºÇ÷¹ÀÌ Å©±â: 1.9 ÀÎÄ¡ ¹× ¹Ø¿¡
- ÀÛdz: ½ºÅĵù ¹× º®°ÉÀÌ
- ºê·£µå À̸§: ZUIDID
- ±Ù¿ø: CN (Á¤Ç°)
Description:
SHT2000 Temperature and Humidity Controller Operating Instructions
Product Name: Temperature and Humidity Controller
Product Model: SHT2000
Supply voltage: AC 110~230V
Power supply frequency: 50/60Hz
Temperature range: -20~60degC
Humidity range: 0%~100%RH
Temperature measurement accuracy: 0.3
Humidity measurement accuracy: 3%
Output Control: Relay Output
Output Power: MAX 10A
Setting method: Start value
Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)
Heating/cooling mode setting:
Setting mode: setting (starting temperature): Press and hold the ¡ã button to start the temperature flashing. Use ¡ã¡å key to set the starting temperature value.
Setting (stop temperature): Press and hold the ¡å button to stop the temperature flashing. Use ¡ã¡å to set the stop temperature value.
Heating use case: control the water heater, heat to 65 deg C to stop, the temperature drops back to 50 deg C and start heating again
Step 1: heating mode, starting temperature
Step 2: Press and hold the ¡ã button to start the temperature flashing. Use ¡ã¡å to set the starting temperature to 50 degC.
Step 3: Press and hold the ¡å button to stop the temperature flashing. Set the stop temperature to 65 degC with ¡ã¡å keys, and the setting is completed!
Refrigeration use case: use in the farm, the fan is ventilated to 26 deg C to stop, the temperature is raised to 30 deg C and the ventilation is started again.
Step 1: cooling mode, starting temperature > stop temperature
Step 2: Press and hold the ¡ã button to start the temperature flashing. Use ¡ã¡å to set the starting temperature to 30 degC.
Step 3: Press and hold the ¡å button to stop the temperature flashing. Use ¡ã¡å to set the stop temperature to 26degC. The setting is completed!
Humidification/Dehumidification Mode Settings:
Setting (start humidity): Press and hold ¡â key to start the humidity value flashing. Set the humidity value by ¡â ¡ä key. Set [Stop Humidity]: Press and hold ¡â key to stop the humidity value flashing, and set the humidity to stop by ¡â ¡ä key value.
Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification.
Setup steps:
Step 1: Press and hold the ¡â button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH.
Step 2: long press the ¡ä button for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.
Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps:
Step 1: Press and hold the ¡â button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH.
Step 2: Press and hold the ¡ä button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.