aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ¸ðµ¨ ¹øÈ£: Kew6205
- ºê·£µå À̸§: GRAIGAR
- ±Ù¿ø: CN (Á¤Ç°)
Kyoritsu6205 Portable Appliance Testers KEW6205 Digital Resistance Gauge Measuring Instrument 10MA and 30MA 's Measurement Protect life and property from faulty appliances .Battery operated .PASS / FAIL result .Color status back light .10 mA & 30 mA RCD test(Isolation transformer built in)
Memory function up to 999 data .Printer output .Complies to AS / NZS 3760
Mains voltage indlcationDisplay range | 30V-270V | Accuracy | ¡¾5V |
Protective conductor resistance testMeasuring range | 0.00-20.00¥Ø | Open circuit voltage | 5V¡¾0.4V DC | Measuring current | 200mA DC(nominal value) | Accuracy | ¡¾3%rdg¡¾5dgt |
Insulation resistance testRated volatge | 250V | 500V | Measuring range | 0.00-20.00M¥Ø | No-load voltage | 250V DC +20%,-0% | 500V DC +20%,-0% | Short circuit current | 1.5mA DC or less | Accuracy | ¡¾2%rdg¡¾3dgt |
Load current/Leakage current testItem | Load current | Leakage current | Mains voltage range | 100-253V/50Hz | Measuring range | 0.10-10.00A rms | 0.10-20.00mA rms | Accuracy | ¡¾10%rdg¡¾5dgt | ¡¾3%rdg¡¾5dgt |
RCD testRated voltage | 230V -15%?- +10%/50Hz | Rated current | 10mA/30mA | Function | ¡¿ 1 | ¡¿ 5 | Test duration | 0.0ms-500.0ms | 0.0ms-40.0ms | Operating time accuracy | ¡¾2ms(<=40ms),¡¾8ms(>40ms) |
GeneralPower source | LR6(AA)(1.5V) ¡¿ 6 | Applicable Standards | IEC/EN61010-1 CAT II 300V, IEC/EN61010-2-030, IEC/EN61010-031, EN61326-2-2, AS/NZ3760 | Dimensions / Weight | 261(L) ¡¿ 104(W) ¡¿ 57(D)mm / Approx. 930g(including batteries) | Included Accessories | 7277(Mains lead), 7129A(Test lead with Alligator clip), 7161A(Flat test prod), 7276(Adaptor for Extension cord), 9193(Carrying case), 8928(Fuse[10A/250V]), 9121(Shoulder strap), Buckle, Instruction manual |
|
|
|
|
|