ow.productDescripti ETCR7300A Large Caliber Three Phase Power Tester Store 200 Sets Of data, With RS232 Interface ETCR7300A Large Caliber Three Phase Power Tester is well designed and manufactured for measuring three phase AC voltage, current, leakage current, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence, active power, reactive power, apparent power, power. It is a multifunctional, digital, intelligent tester. Its large caliber 80mm×80mm can clamp electric cable of 80mm diameter, or 96mm×4mm flat cable and steel earth wires. It has all the functions of Large Caliber Leakage Clamp Meter and Micro Power Clamp Meter. Besides, it also has this functions such as distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc. Provide operators with a safe, accurate and convenient tester. ETCR7300A Large Caliber Three Phase Power Tester’s clamp core is made of special alloy, adopt the latest magnetic shielding techniques, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement. The meter can store 200 sets of data, with RS232 interface, upload stored data to the computer through the system software, implementing online real-time monitoring, historical inquires, dynamic display. With the function of historical data read, export, print, and backlight, data hold, etc. It is a necessary tool for electrical safety testing. Technical Specification Function | Measure three phase AC voltage, leakage current, current, active power, reactive power, apparent power, power, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence | Power | 6V DC(LR6×4 alkaline dry batteries, continuously working for 12 hours) | Test Mode | Clamp CT, integral mode | Clamp Size | 80mm×80mm(can clamp electric cable of 80mm diameter, or 96mm×4mm flat cable and steel earth wires) | Current Range | AC 0.0A-2000A, Resolution: 0.1A | Power Range | AC 0.0KW-1200KW, Resolution: 0.1KW | Voltage Range | AC 0-600V, Resolution: 0.01V | Frequency Range | 25Hz-100Hz, Resolution: 0.1Hz | Phase Range | 0.0°-360.0°, Resolution: 0.1° | Power Factor Range | 0.3-1.0(Capacitive or inductive) , Resolution: 0.001 | Power Energy Range | 0.0000KWh-72000KWh, Resolution: 0.0001KWh | Measured Wire Position | Measured wire at approximately the geometric center of the clamp | Data Storage | 200 sets, “FULL the memory is full ” symbol indicate | RS232 Interface | With RS232 interface, download data to computer for analysis and management | Communication Wire | RS232 communication wire, 1.8m | Frequency | 50Hz ,60Hz automatic identification | Gear Shift | Automatic shift | Sample Rate | About 2 times/second | Line Voltage | Below AC 600V line measurement | Display Mode | LCD: 128dots×64dots; Display area: 43mm×29mm | Meter Size | Length 275mm × Width 145mm × Height 40mm | Backlight | Controlled by “ * " key | Data Hold | "HOLD" symbol appears | Overflow | "OL" symbol appears | Automatic Shutdown | Automatically shutdown about 15 minutes after power on to reduce battery consumption | Voltage Detection | Low battery symbol appears to remind the replacement of battery when the battery voltage drops below 5.2V. | Weight | 1kg(with batteries and accessories) | Working Current | 50mA with enabled backlight; 25mA with disabled backlight | Working Temperature and Humidity | -10¡É-40¡É; 80%rh | Storage Temperature and Humidity | -10¡É-60¡É; below 70%rh | Insulation strength | AC 3700V/rms(between core and shell) | Safety Specifications | IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT ¥²(600V) | Accessories | Meter: 1 PC; Test Wires: 4 PCS (Yellow, Green, Red, Black), RS232 Data Wires: 1PC; Disk: 1 PC; Battery(LR6): 4PCS; Meter Box: 1 PC | Field Application 1) We accept Alipay, West Union, TT. All major credit cards are accepted through secure payment processor ESCROW. 2) Payment must be made within 3 days of order. 3) If you can\'t checkout immediately after auction close, please wait for a few minutes and retry Payments must be completed within 3 days. 1.WORLDWIDE SHIPPING. (Except some countries and APO/FPO)2. Orders processed timely after the payment verification.3. We only ship to confirmed order addresses. Your order address MUST MATCH your Shipping address.4. The images shown are not the actual item and are for your reference only. 5. SERVICE TRANSIT TIME is provided by the carrier and excludes weekends and holidays. Transit times may vary, particularly during the holiday season. 6. If you have not received your shipment within 30 days from payment, please contact us. We will track the shipment and get back to you as soon as possible with a reply. Our goal is customer satisfaction! 7. Due to stock status and time differences, we will choose to ship your item from our first available warehouse for fast delivery. 8.DeliveryTime: If your cargo weighs up to 20KG or above, or you need larger quantity, please contact us or email to us, we will provide you new packing specifications, then try our best to save some transport costs for you, and so that the product price can be of some benefit to you! We are a large manufacturing enterprise groups in China, we sell through Alibaba, there is only purpose ,it is to better promote our products,all our company products are shipped direct from the factory, please contact us , hope to establish long-term friendly and mutual cooperation relations between each other ! We provide 6-12 months warranty. If the item is defective, please notify us within 3 days of delivery. All items must be returned in their original condition, in order to qualify for a refund or exchange of goods. Items returned after 15 days of delivery are only eligible for repair. The buyer is responsible for all shipping cost. When buying, it means the buyer have given tacit consent to the policy. If further details, please feel free to contact us, we will work with you to reach win-win. We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important We request that you contact us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns. It is impossible to address issues if we do not know about them! `;
|
|
|
|
|