1Pcs DC 0-600V / 200A voltage ammeter two-color display led panel digital voltmeter ammeter power supply yellow blue font
D85-3051AG digital DC voltage and current dual display
Please select the appropriate measurement specifications according to the equipment.
Please measure 0-19.99V and the resolution is 0.01V within 0-20V. Within the range of 0-200V, check 0-199.9V and the resolution is 0.1V. Check 0-600V within 0-600V. Resolution 1V.
The measurement current is checked to 1.99A within 0-2A with a resolution of 0.001A. Within the measurement current 0-10A, 10.00A is selected and the resolution is 0.01A. Check the current within 0-20A and check 19.99A with a resolution of 0.01A. Within the measurement current 0-50A, check 50.0A with a resolution of 0.1A. Check the current within 0-100A and check 100A with a resolution of 0.1A. For measurement 0-200A, please check 200A, resolution 1A. There are no options in the measurement specifications. Please select other measurement specifications. Note: 199.9V 300A......
Please read the following instrument operation and instruction manual carefully when purchasing the order.
1. Measurement accuracy: 1% plus or minus 2 words
2. Display: LCD HD LCD color two-color display
3. (screen visible size: 43 * 25mm)
4.178° wide viewing angle (watching no dead ends)
5. Measurement range: DC voltage (1) DC0-19.99V, 0-199.9V, 0-600V (additional working power supply between 5-30V is required) (2) Measure the voltage between DC5-30V (measured voltage can be As the working power of the meter, the meter does not need to increase the working power, but the measured voltage can only be measured from 5V, and can`t be measured below 5V. If you need to start testing from 0V or the measured voltage is higher than 30V, you must add another set of 5-30V. The working power, please pay attention to the customer when using this!
DC current: DC0-1.999A, 0-10.00A, 20A/75mV, 50A/75mV 100A/75mV, 200A/75mV...
6. Power consumption: <0.5VA
7. Measurement speed: about 2 times per second
8. Dimensions: 70*40*39mm
9. Installation size: 68*38mm
Extreme working conditions:
Working temperature: -10 ~ +50 ° C
Working humidity: 10~80% (no condensation)
Working pressure: 80 ~ 106kPa
Sunlight: no direct illumination
Note 1
:
When wiring, the user must strictly follow the wiring diagram of the wiring diagram corresponding to the wiring diagram. The shunt must be connected to the negative pole of the power supply. The measured load must be connected to the positive terminal of the power supply. If you do not follow the wiring method shown in the wiring diagram, the instrument will be burned (discarded)! Once burned we don`t have to sell!
Note 2
:
The current will not be displayed after a voltage is applied. The current is also connected. The whole circuit can be connected: 2: The shunt with the meter current of the shunt should be connected!
Customers ordering meters with a current measurement range of less than 10A (including 10A), the meter has a built-in shunt, and the customer does not need an external shunt when in use. If the instrument purchased by the customer has a measuring range of 10A or more, and there is no shunt inside the meter, the customer needs to purchase a separate shunt that has the same specifications as the meter. For example, if the current measurement range of the purchased instrument is 0-50A, then another 50/75mV shunt must be purchased, and the purchased shunt must be connected to the purchased shunt regardless of the measured current greater or less than 10A! For the shunt, please click on the picture below or purchase the shunt in our store and add it to the shopping cart (unless the customer owns the matching shunt)