Features:
1.According to IEC61010-1 CAT 3 1000V
2.Dual display, the main display a maximum of 6600
3.Automatic / manual range
4.AC RMS measurement
5.AC voltage / current linear frequency measurement
6.AC voltage 1KHz low pass filter
7.The minimum / maximum / average / measuring relative value
8.Insulation resistance maximum 2G
9.The test voltage 50V/100V/250V/500V/1000V
10.With the polarization index (PI) / induced absorption ratio (DAR) display
11.External voltage detection
12.Timing measurement function
13.The battery voltage detection / low pressure indicator
14.Automatic shutdown function
15.Can record 100 data
Technical indicators:
1.DC voltage: 660mV/6.6V/66V/660V/1000V +-0.5%
2.AC voltage: 660mV/6.6V/66V/660V/750V +- 1.5%
3.DC: 60mA/400mA +- 1%
4.Alternating current: 60mA/400mA+- 1.5%
5.Resistance: 660kohm/6.6k kohm /66k kohm /660k kohm +- 1.2% 6.6M kohm /66M kohm +- 2%
6.Capacitance: 6.6nF/66nF/660nF/6.6uF/66uF/660uF/6.6mF/66mF +- 5%
7.Temperature: -30 C ~1000 C +- 1%
8.Insulation resistance: the input voltage range error (accuracy)
9.50V (0%~20%) 0~50M +- 3%
10.100V (0%~20%) 0~100 M +- 3%
11.250V (0%~20%) 0~250 M +-3%
12.500V (0%~20%) 0~500 M +-3%
13.1000V (0%~20%) 0~499 M +- 3%
14.500 M kohm~2G kohm +- 5%
Characteristic:
*According to IEC/EN 61010-1 1000V CAT 3, 600 V CAT IV measurement standard
*1000V 750V DC voltage, AC voltage (RMS)
*6600 Count count (capacitance, temperature, insulation except)
*When the input terminal V and COM terminal: when the voltage measurements, the maximum
overload protection *voltage 1200V, other protection overload voltage 250V measurements
(RMS)
*When the input terminal mA and terminal COM, 400mA overcurrent protection; when the input
terminal Hi and Lo terminal voltage, overload protection 600V
*Fuse: 400 mA, 1000 V, fast acting fuse
*Batteries: 4 1.5V AA alkaline batteries; insulation test, for at least 1000 insulation
test (1000V test conditions, 1M kohm and 5 seconds start and 25 seconds off the duty factor
of standard test)
*Insulation test range: 0.01 M kohm.0G kohm ~2
*Insulation test voltage: 50, 100, 250, 500, 1000 V
*Insulation test output voltage accuracy: +20%, -0%
*Insulation test and short circuit test current: 1.5 mA nominal value
*Insulation test automatic discharge time: capacitance (C) = 1 F or more hours, discharge
time < 1
*Insulation test circuit detection: in the test initialization before, if the terminal
voltage is greater than 20 V, the alarm test.
*Insulation test maximum capacitance capacitive load: 1 F the following can be operated.
*Storage temperature: -20 C ~60 C
*Operating temperature: 0 C ~40 C
*Storage of altitude: 12000m
*Using altitude: 2000m CAT 1000V 3000m CAT 2 1000V 3.
*Temperature coefficient: the temperature lower than 18 C or above 28 C, coefficient of
each ( C) * 0.05 * (the specified accuracy)
*Relative humidity: 40%~75%
*Size: 205 (L) * 102 (W) * 58 (H) mm
*Weight: about 390 G
Annex:
*Test lead X2
*The crocodile clip X2
*K type thermocouple X1
*Manual X1
*Multifunctional socket X1