Packaging Details
- Unit Type: piece
- Package Weight: 0.8kg (1.76lb.)
- Package Size: 20cm x 10cm x 5cm (7.87in x 3.94in x 1.97in)
Working Principle:
Utilization the thermosensitive element principle,atuo regulation the proportion of coldwater and hot water to make outlet water temperature kept constant.so get the the effect of constant temperature.
Feature:
1.Work pressure:0.05Mpa - 1Mpa
2.Ideal pressure:0.1Mpa - 0.5Mpa.Installation pressure rudicing valve when exceed ideal pressure.
3.Standard pressure: Dynamic pressure0.30.02Mpa.
4.Cold water supply temperature: 4-29 hot water supply temperature: 55-85. Advice water supply temperature55- 70.
5.Out water tempertature range: 20-50.
6.Set the safety temperature at 38.
7.Satety characteristic: If cold water supply fails,flow rate will be reduced to virtually shut off which avoid the risk of scalding.
8.Temperature accuracy:Kept constant ±1 for the setting.
9.Out water temperature stability:when the temperature of water intake kept constant, Cold water or hot water pressure change 50% , the outlet water temperature changes in ±2 °C of setting temperature. The supply water pressure kept constant;the temperature for hot water supply can be increases from 60 to 75 (5/min), the outlet water temperature changes in ±2 °C of setting temperature.
10.Complies with the following standard: ASMEA112.1812005/CSAB125.1-05,ASSE1016,EN1111,AS-4032.1 and QB2806-2006.
Product Introduction
Constant temperature mixing valve is designed for solar water heaters, central heating facilities of the products, mainly used in solar water heaters, electric water pipes and central heating facilities Users can adjust their own temperature as needed Of. at First setting up the required temperature,After 5 s in the water, you will be able to reach the required temperature.The outlet water temperature. kept constant ±1 for the setting.and the maximum discharge can achieve 1620L/min,enough to your needs. The product imported temperaturecontrol rods from france.the Effect of kept constant is Stability.when the temperature of water intake kept constant temperature, Cold waterOr hot water pressure change 50% , The outlet water temperature change in ±1To setting temperature;the supply water pressure kept constant; supply water temperature Rise to 755/min from 60, outlet water temperature change in ±1 to setting temperature; cold water lack probability in 5s, outlet water will Will atuo shut. Effective avoid scalded.
-->