![](https://ae01.alicdn.com/kf/Hc0e8bc6926ac4dc4b1398cd44ce83345T/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H4bdae56bee8c48c5947db90c4539ff51U/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H8ce79d611c6c4deaba0f284b02e39a57V/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H11719f7cb7014da4b645f7d75c053dc7a/CHB-PID-220V.jpg) aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/Hc0e8bc6926ac4dc4b1398cd44ce83345T/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H4bdae56bee8c48c5947db90c4539ff51U/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H8ce79d611c6c4deaba0f284b02e39a57V/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H11719f7cb7014da4b645f7d75c053dc7a/CHB-PID-220V.jpg) ![](https://ae01.alicdn.com/kf/H52de495ec5184706a3fb15b0818d2247Z/CHB-PID-220V.jpg)
- ½º¸¶Æ® ±â±â: no
- ÀÌ·Ð: ¿Âµµ Á¶Àý±â
- »ç¿ë¹ý: Industrial
- ¸ðµ¨ ¹øÈ£: CHB
- ´ëÇü È°ÀÚ: DIGITAL
- Èû À¯Çü: ÃæÀü±â
- ÀÛdz: ÀÓº£µðµå
- ºê·£µå À̸§: CKCTINNER
- ±Ù¿ø: CN (Á¤Ç°)
¿É¼ÇÁ¤º¸[(350850)CHB102-Relay] [(350852)CHB102-SSR] [(350853)CHB402] [(10)CHB702] [(29)CHB902]![](https://ae01.alicdn.com/kf/H52de495ec5184706a3fb15b0818d2247Z/CHB-PID-220V.jpg_640x640.jpg)
Model number and parameters
Model number |
External dimensions |
Perforation dimensions |
REX-CH102 |
48x48x75 mm |
45 0.50x45 0.50 mm |
REX-CH402 |
48x96x75 mm |
45 0.50x92 0.50 mm |
REX-CH502 |
96x48x75 mm |
92 0.50x45 0.50 mm |
REX-CH702 |
72x72x75 mm |
68 0.50x68 0.50 mm |
REX-CH902 |
96x96x75 mm |
92 0.50x92 0.50 mm |
General
Model number |
CHB series |
Accuracy |
±0.5%FS±1°C |
Supply voltage |
48-240V |
Input types |
Thermocouple: K, J, R, S, B, E, N, T, W5Re/W26Re, PLII RTD: Pt100, JPt100 Voltage: 0-5V, 1-5V Current: 0-20mA, 4-20mA |
Output types |
Electromagnetic relay + SSR |
Power consumption |
AC100-240V: under 10VA; AC24V: under 5VA; DC24V: under 160mA |
Control method |
PID, or ON/OFF |
Setting method |
Touch switch |
Indication method |
8-segment 4-digital display and LED indication |
Alarms |
1. Alarm quantity: Default is 1pcs, if 2pcs, need to be customized 2. Alarm form: N: No alarm A: Deviation low B: Deviation high C: Deviation high/low D: Band E: Deviation high with hold action F: Deviation low with hold action G: Deviation high/low with hold action H: Process high J: Process low K: Process high with hold action L: Process low with hold action |
Operating temperature |
0 to 50 °C (32 to 122 °F) |
Operating humidity |
30-85% RH max, non-condensing |
Alias name |
CHB series pid temperature controller, intelligent temperature controller
|
|
|
|
|
|