The temperature data can be stored in the background, and the frequency of log uploading can be set. The fastest time can be set to 1s / piece (one piece in 5 minutes by default); You can query the data of any time period at will, and retain the data within 15 days at most; In the later stage, the cloud data export function can be added to facilitate the next step analysis of temperature dataParameters
Temperature display: digital tube display
Supply voltage: DC 6-30V
USB power supply: support
Temperature control range: -40-110°C
Temperature control accuracy: 0.1¡É
NTC temperature measurement range: -40-110¡É
Whether to support 18B20: Yes (-40-110°¡É)
Output type: relay switch, current within 10A
Alarm notification: support WeChat alarm notification
Cloud data record: 15 days cloud record, can be exported at any time
Timer switch function: support
1.1 Function description of automatic mode:
1) First select heating mode/cooling mode;
2) Set the temperature and hysteresis difference, if you need to delay start, set the time of delay start;
3) If you need to set high and low temperature alarms, set the high and low temperature alarm thresholds yourself;
1.2 Description of heating mode:
When the detected temperature (current temperature) ¡Â set temperature - hysteresis temperature, the relay is turned on, and the heating equipment starts to work;
When the detected temperature (current temperature) ¡Ã the set temperature, the relay is disconnected and the heating device stops working;
Example: Set the temperature to 30¡É and the return temperature to 5¡É;
When the temperature is 20¡É¡Â25¡É (30-5 = 25), the relay pulls in and starts to heat, and when the temperature reaches 30¡É ¡Ã the set temperature of 30¡É, the relay turns off and stops heating;
1.3 Description of cooling mode:
When the detected temperature (current temperature) ¡Ã set temperature + hysteresis temperature, the relay is turned on, and the refrigeration equipment starts to work;
When the detected temperature (current temperature) ¡Â the set temperature, the relay is disconnected and the refrigeration equipment stops working;
Example: Set the temperature to 30°C and the return temperature to 5°C;
When the temperature is 36°C ¡Ã 35°C (30+5 = 35), the relay pulls in to start cooling, and when the temperature reaches 30°C ¡Â the set temperature 30°C, the relay turns off and stops cooling;
1.4 Description of delayed start function:
After a heating/cooling process is over, how long to delay (unit: seconds) to allow the next heating/cooling;
1.5 Temperature correction function:
If the system works for a long time, there may be deviations, which can be corrected by this function, the current temperature = measured temperature + calibration value;
1.6 High and low temperature alarm function:
Buzzer on and off: After it is turned on, the buzzer will sound after the alarm, and when the button is pressed, the buzzer will stop sounding;
High temperature alarm: After the high temperature alarm is turned on, the relay is disconnected when the current temperature is higher than the high temperature alarm temperature;
Low temperature alarm: After the low temperature alarm is turned on, the relay is disconnected when the current temperature is lower than the low temperature alarm temperature;
1.7 Emergency braking function (emergency stop function):
After the emergency stop is turned on, the relay will be disconnected no matter what state it is in; after the emergency stop is turned off, the relay returns to the normal state;
1.8 Whether the product can be disconnected and run offline in automatic mode:
In the automatic mode, when the parameters are set, the product can be disconnected from the network and run offline, and the parameters will not be lost when the power is turned off.
1.9 LAN data export function:
The local area network will upload a piece of temperature data in 1 second. After clicking "Export", it will be automatically exported to EXCEL for analysis of the temperature data.
2.1 manual mode function description
In manual mode, timing, delay, cycle and inching can be set;
2.2 power on status setting description
Power on State - on: the relay is closed by default after power on;
Power on State - off: the relay is off by default after power on;
Power on State - hold: after power on, the relay state before power off is automatically restored
2.3 whether the product can run offline under manual mode
In the manual mode, the product cannot be disconnected from the network and run offline.
2.4 description of other functions in manual mode
Other functions are the same as in automatic mode
3. sharing settings
It can be shared with others, so that multiple people can share a device, and their functions can be controlled.
4. operation records
All operation records can be stored in the background. The mode of power on + timer + keys + APP + heating and cooling is convenient to query the relay action status;
5. cloud recording and uploading frequency
The temperature data can be stored in the background, and the frequency of log uploading can be set. The fastest time can be set to 1s / piece (one piece in 5 minutes by default); You can query the data of any time period at will, and retain the data within 15 days at most; In the later stage, the cloud data export function can be added to facilitate the next step analysis of temperature data