Feature:
1. Multi?purpose clamp meter with large LCD screen, which can clearly display the measurement results.
2. 6000 counts, multi?function measurement, easy to use, fast and accurate measurement, high accuracy.
3. Using high?quality ABS material, it is resistant to fall and durable, has a long service life, and is not easy to damage the equipment.
4. The fuselage is ergonomically designed, comfortable to hold, practical and beautiful.
5. Lightweight, portable and easy to carry, it doesn`t take up space, practical, it is suitable for professional and home use.
Specification:
Item Type: Clamp Meter
Material: ABS
Color: Red
Model: ST208
Battery: 1.5V 2 x AAA batteries (not included)
Application: Electricity test
DC Voltage/AC Voltage Automatic Scanning Test (DCV/ACV)
|
Range/accuracy
|
6000counts
|
Resolution
|
DC/AC6V
|
¡¾(0.5%+3)
|
0.001V
|
DC/AC60V
|
0.01V
|
DC/700V
|
0.1V
|
AC500V
|
¡¾(0.8%+10)
|
1V
|
Input Impedance: 10M¥Ø; Overload protection: 700V DC or 500V AC peak value.
|
Resistance (¥Ø)
|
Range/accuracy
|
6000counts
|
Resolution
|
600¥Ø
|
¡¾(0.8%+5)
|
0.1¥Ø
|
6K¥Ø
|
¡¾(0.8%+3)
|
1¥Ø
|
60K¥Ø
|
10¥Ø
|
600K¥Ø
|
100¥Ø
|
6M¥Ø
|
1K¥Ø
|
60M¥Ø
|
¡¾(2.5%+3)
|
10K¥Ø
|
Input Impedance: 10M¥Ø; Overload protection: 700V DC or 500V AC peak value.
|
Fast Continuity Test/Diode/Capacitor
|
Range
|
Display Value
|
Test Condition
|
."__"
|
Diode Forward Voltage Drop
|
The buzzer sounds for a long time, and the resistance value of the test two points is less than (50 ¡¾ 20) 2
|
The buzzer sounds for a long time, and the resistance value of the test two points is less than (50 ¡¾ 20) 2
|
Open circuit voltage is about 0.4V, press "power" to switch between two functions
|
Capacitance (C)
|
Range/accuracy
|
6000counts
|
Resolution
|
10nF
|
¡¾(3.5%+20)
|
10pF
|
100nF
|
100pF
|
1uF
|
1nF
|
10uF
|
10nF
|
100uF
|
100nF
|
1mF
|
1uF
|
10mF
|
10uF
|
60mF
|
100uF
|
Overload protection: DC700V, AC500V
|
AC current (ACV A)
|
Range/accuracy
|
|
Resolution
|
60A
|
¡¾(2%+30)
|
0.001A
|
600A
|
0.1A
|
Maximum measured pressure drop: 600mA; overload protection: 10A
|
How to Use
DC Voltage/AC Voltage Automatic Scanning Test (DCVIACV)
1. Long press POWER for more than 2S, and it will display automatic scanning state-"---" when it is turned on.
2. Insert the black test lead into the "COM" jack and the red test lead into the "V/¥Ø" jack; the test lead reliably touches the test point.
3. When the measured voltage between the input ports "COM" and "VR" is greater than 0.6V, regardless of the AC voltage or the DC voltage, the meter will compare the DC component and the AC component, take the larger component signal, and then measure it according to the The value is automatically switched between 6V/60V/600V/DC700V (AC500V), and then the measured value is displayed on the LCD.
Resistance (¥Ø) Test
1. The boot display is in the automatic scanning state "___".
2. Insert the black test lead into the "COM" jack and the red test lead into the "V/¥Ø" jack; the test lead reliably touches the test point.
3. If the measured resistance at both ends of the test lead is less than 50¥Ø, the buzzer will emit a continuous beep, and quick buzzer measurement is required. Please press the power key to enter the buzzer quick measurement.
4. If you are measuring the resistance of a closed loop, you must discharge the resistance at both ends of the resistance to be measured. Otherwise, if the voltage in the loop is greater than 0.6V, the meter will mistake it for voltage measurement and enter the voltage measurement mode.
5. Input the resistance measurement value between the input port "COM" and "V/2", the meter will automatically switch between 600¥Ø/6k¥Ø/60k¥Ø 600k¥Ø/6M¥Ø/160M¥Ø according to the resistance measurement value, and then the measured value will be in Displayed on the LCD.
Capacitance Test
1. The boot display is in the automatic scanning state "__".
2. Insert the black test lead into the "COM" jack and the red test lead into the "V/Q" jack: the test lead reliably touches the test point.
3. If you need to quickly continuity test diode/capacitance measurement, constantly trigger the "power" switch, enter the rapid continuity test/diode/capacitance measurement in one cycle, select the corresponding function measurement according to the measurement needs, and measure the capacitance. The size of the capacitance will automatically select different ranges, and the measured value will be displayed on the LCD. The capacitance measurement range is 10nF/100nF/1uF/10uF/100uF/1mF/10mF/60mF.
AC Current Test
1. Press the handle 10, according to the size of the measuring wire, slowly open the mouth of the clamp head, and pass any one of the current wires to be measured vertically through the center of the clamp head, and the meter will automatically switch to the corresponding according to the size of the measured current As shown in Figure 1 on the range, the measured current value and the current polarity of the red test pen point will be displayed on the screen at the same time. The clamp meter can only measure one conductor at a time. If two or more conductors are measured at the same time, the measurement reading will be wrong.
2. In the current measurement state, the measurement probe between "VR" and "COM" should be unplugged due to the large measurement current.
3. The automatic recognition of the current must ensure that there is no interruption between the test leads, and the loop can be automatically measured.
Package List:
1 x Clamp Meter(Battery Not Included)
2 x Test Lead
1 x Portable Bag
1 x English Manual