- Â÷¿ø: 7.8cm*3.7cm
- ÀÛµ¿ ¿Âµµ: -10-60degree
- Ãâ·Â Àü¾Ð: 220V
- Á¤È®µµ µî±Þ: 1.0
- ÃøÁ¤ ¿¡³ÊÁö ¹üÀ§: 100A/22000W
- ´Ü°è: ´Ü»ó
- ¸ðµ¨ ¹øÈ£: PZEM-004T
- ÃÖ´ë ÀÛµ¿ Àü·ù: 100A-119A
- Á¤°Ý Àü¾Ð: 220V
- Àü¿ø °ø±Þ: AC
- ´ëÇü È°ÀÚ: µðÁöÅÐ Àü¿ë
- DIY ¿ëÇ°: Àü±â
- ºê·£µå À̸§: peacefair
- ¿ø»êÁö: Áß±¹
- Communicate Port: TTL
- Current range: 0-100A
- Voltage range: 80-260V
- Power range: 0-22kw
- Power factor: 0.1
- Frequency: 45-65Hz
¿É¼ÇÁ¤º¸[(350686)V1.0 004T NO Box][(350850)V3.0 004T With Box]
1.1.1 Measuring range:80¢¦260V 1.1.2 Resolution: 0.1V 1.1.3 Measurement accuracy: 0.5% 1.2 Current 1.2.1 Measuring range: 0¢¦10A(PZEM-004T-10A); 0¢¦100A(PZEM-004T-100A) 1.2.2 Starting measure current: 0.01A(PZEM-004T-10A); 0.02A(PZEM-004T-100A) 1.2.3 Resolution: 0.001A 1.2.4 Measurement accuracy: 0.5% 1.3 Active power 1.3.1 Measuring range: 0¢¦2.3kW(PZEM-004T-10A); 0¢¦23kW(PZEM-004T-100A) 1.3.2 Starting measure power: 0.4W 1.3.3 Resolution: 0.1W 1.3.4 Display format: £¼1000W, it display one decimal, such as: 999.9W ¡Ã1000W, it display only integer, such as: 1000W 1.3.5 Measurement accuracy: 0.5% 1.4 Power factor 1.4.1 Measuring range: 0.00¢¦1.00 1.4.2 Resolution: 0.01 1.4.3 Measurement accuracy: 1% 1.5 Frequency 1.5.1 Measuring range: 45Hz¢¦65Hz 1.5.2 Resolution: 0.1Hz 1.5.3 Measurement accuracy: 0.5% 1.6 Active energy 1.6.1 Measuring range: 0¢¦9999.99kWh 1.6.2 Resolution: 1Wh 1.6.3 Measurement accuracy: 0.5% 1.6.4 Display format: £¼10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh ¡Ã10kWh, the display unit is kWh, such as: 9999.99kWh 1.6.5 Reset energy: use software to reset. 1.7 Over power alarm Active power threshold can be set, when the measured active power exceeds the threshold, it can alarm 1.8 Communication interface RS485 interface 1 Communication protocol 1.1 Physical layer protocol Physical layer use UART to TTL communication interface Baud rate is 9600, 8 data bits, 1 stop bit, no parit
Features:
1.1.1 Measuring range:80¢¦260V 1.1.2 Resolution: 0.1V 1.1.3 Measurement accuracy: 0.5% 1.2 Current 1.2.1 Measuring range: 0¢¦10A(PZEM-004T-10A); 0¢¦100A(PZEM-004T-100A) 1.2.2 Starting measure current: 0.01A(PZEM-004T-10A); 0.02A(PZEM-004T-100A) 1.2.3 Resolution: 0.001A 1.2.4 Measurement accuracy: 0.5% 1.3 Active power 1.3.1 Measuring range: 0¢¦2.3kW(PZEM-004T-10A); 0¢¦23kW(PZEM-004T-100A) 1.3.2 Starting measure power: 0.4W 1.3.3 Resolution: 0.1W 1.3.4 Display format: £¼1000W, it display one decimal, such as: 999.9W ¡Ã1000W, it display only integer, such as: 1000W 1.3.5 Measurement accuracy: 0.5% 1.4 Power factor 1.4.1 Measuring range: 0.00¢¦1.00 1.4.2 Resolution: 0.01 1.4.3 Measurement accuracy: 1% 1.5 Frequency 1.5.1 Measuring range: 45Hz¢¦65Hz 1.5.2 Resolution: 0.1Hz 1.5.3 Measurement accuracy: 0.5% 1.6 Active energy 1.6.1 Measuring range: 0¢¦9999.99kWh 1.6.2 Resolution: 1Wh 1.6.3 Measurement accuracy: 0.5% 1.6.4 Display format: £¼10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh ¡Ã10kWh, the display unit is kWh, such as: 9999.99kWh 1.6.5 Reset energy: use software to reset. 1.7 Over power alarm Active power threshold can be set, when the measured active power exceeds the threshold, it can alarm 1.8 Communication interface RS485 interface 1 Communication protocol 1.1 Physical layer protocol Physical layer use UART to TTL communication interface Baud rate is 9600, 8 data bits, 1 stop bit, no parit
|
|
|
|
|