FR2000C+ Multifunction Ground Earth Resistance Meter 0-1200¥Ø Current Tester 0.00mA-20A Loop Non Contact Detecter 300 Group Save
¥°. Characteristic
FR2000+ series clamp grounding resistance tester is a new generation of grounding resistance tester carefully developed by our company`s technical team. It adopts a new generation of LCD black screen backlight display and microprocessor technology. It is convenient and quick to measure the grounding resistance. When measuring the grounding system with loop, there is no need to disconnect the grounding down-conductor or auxiliary electrode, which is safe and fast. Widely used in telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc. The instrument has the characteristics of accurate, fast, simple, stable and reliable testing.
FR2000+ series clamp earth resistance tester is controlled by microprocessor, which can accurately detect earth resistance and leakage current. It uses fast filtering techniques to minimize interference. Store 300 sets of data at the same time.
¡ÚResistance range: 0-1200¥Ø
¡ÚCurrent range: 0-20A
¡ÚNew black screen design, high-end luxury
¡Ú¥Ø + A display on the same screen
¡ÚQuick self-check function, no need to wait
¡ÚUsing fast filtering technology, strong anti-interference ability
¡ÚNew design, long life of clamp head
¡Ú300 groups of storage
¥±. Model comparison
Model |
FR2000A+ |
FR2000+ |
FR2000B+ |
FR2000C+ |
Resistance range |
0.01¥Ø-200¥Ø |
0.01¥Ø- 500¥Ø |
0.01¥Ø-1200¥Ø |
0.01¥Ø-1200¥Ø |
Type |
Practical |
Basic |
Explosion-proof |
Multifunctional |
Resistor Resolution |
0.001¥Ø |
0.001¥Ø |
0.001¥Ø |
0.001¥Ø |
Current range |
N/A |
N/A |
N/A |
0.00mA-20A |
Current resolution |
N/A |
N/A |
N/A |
0.01mA |
¥². Technical Specification
Features |
Ground resistance test, loop resistance test, leakage current test |
Accuracy
|
Ground resistance accuracy: ±1% ±0.01¥Ø |
Current accuracy: ±2%±1mA |
Ambient temperature and humidity |
23¡É±5¡É, below 75%rh |
Power supply |
DC 6V (4 AA alkaline dry batteries) |
Measurement method |
mutual inductance |
Jaw size |
55mm×32mm |
¥Ø + A synchronized display |
¥Ø + A display on the same screen |
Display mode |
4-digit LCD display, black screen design |
LCD size |
46mm×29mm |
Meter size |
Length, width and height: 285mm×85mm×58mm |
Measure time |
2 times/sec |
Data storage |
300 groups, "MEM" storage indication, displaying "FULL" symbol means the storage is full |
Data access |
"MR" symbol indication when viewing data |
Overflow display |
"OL" symbol indication when overrange overflow |
Interference test |
Automatically identify interference signals, and the "NOISE" symbol indicates when the interference current is large |
Alarm function |
When the measured value exceeds the alarm setting value, an alarm prompt will be issued |
Battery voltage |
Real-time display of battery power, reminding to charge in time when the battery voltage is low |
Automatic shut-down |
"APO" instruction, automatically shut down after 5 minutes of power on |
Power consumption |
50mA Max |
quality |
Meter: 1180g (including battery) |
Working temperature and humidity |
-10¡É¢¦40¡É; below 80%rh |
Storage temperature and humidity |
-20¡É¢¦60¡É; below 70%rh |
Insulation resistance |
Above 20M¥Ø (500V between circuit and case) |
Pressure resistance |
AC 3700V/rms (between circuit and case) |
External magnetic field |
<40A/m |
External electric field |
<1V/m |
Suitable for safety regulations |
IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); |
¥³. Packing List
Meter |
1 set |
Instrument box |
1 |
AA dry battery |
4pc |
Calibration ring |
1 |
Manual, Warranty |
1 set |