Y?150BF 0?0.4MPa Radial Pressure Gauge Stainless Steel Corrosion?Resistant Industrial Small Vacuum Gauge
Feature:
1. Standard pointer configuration, its pointer covers 1/3?2/3 of the shortest graduation line length, which can facilitate you to read more easily.
2. High?quality threaded joints, its joints are made of stainless steel, which enhances the service life and durability of the overall product.
3. Selected materials, all of its materials are carefully made, sturdy and durable, stable performance, so you can use it with confidence.
4. A wide range of applications, it is suitable for pipeline valve, mining, petrochemical and , etc., can help detect pressure conditions.
5. High?accuracy design. As a high?standard instrument, it has high accuracy and can be applied to industrial standards to help grasp the pressure situation in real time.
Specification:
Item Type: Pressure Gauge
Weight: Approx. 985g / 34.7oz
Material: Stainless Steel
Product Diameter: Approx.150mm / 5.9in
Product Length: Approx.22cm / 8.7in
Thread Size: M20x15mm / 0.6in (Not G 1/2)
Measuring Range: 0-0.4MPa; 0-58Psi
Accuracy Level: 1.6
Application: It is suitable for pipeline gate valve, mining, petrochemical and , etc.
Package List:
1 x Pressure Gauge
1 x Manual
How to use: 1. About the instrument, please use it in a place where the ambient temperature is ?40¡É~70¡É and the relative humidity is not more than 90% (the instrument is in the normal working position), please pay attention to the vertical installation.
2. The connection point of the instrument and the measuring point should be at the same level, otherwise the correction value should be added, but it has nothing to do with the measured gas. Generally, the length of the connecting pipe should not exceed 50 meters.
3. In order to reduce the impact, vibration and changes of the measured medium on the instrument, various buffers must be added during use.
4. The meter is suitable for measuring the pressure of non?corrosive media on steel and copper alloy.
5. When measuring the stable pressure, the meter must not exceed 3/4 of the upper limit of the meter`s measurement, and when measuring fluctuating pressure, it must not exceed 2/3 of the upper limit of the meter`s measurement.
6. During the use of the meter, if the accuracy is reduced, the indicating value is unstable or the pointer is jumping, the reason should be found out, and it can be used after re?calibration.
![picture](https://ae01.alicdn.com/kf/HTB1miXBKpXXXXcGXFXXq6xXFXXXv/201747246/HTB1miXBKpXXXXcGXFXXq6xXFXXXv.jpg?size=11837&height=79&width=771&hash=e07c1c5e99f40063fef5f8453f2548fc)
![](https://ae01.alicdn.com/kf/H01153d50b37c40bfa556f429773c7f5do.jpg)
![](https://ae01.alicdn.com/kf/Hf97addae673d467db0df03237223b174G.jpg)