aHR0cDovL2ZyZWVzaGlwLmNvLmty Item specifics - Display Type:
- Digital Only
- Operating Temperature:
- -10 to +55 CEL
- Brand Name:
- OMRON
- Voltage:
- AC100-240V
- Accuracy Class:
- +/- 0.1% +/- 1 digit
- Measuring Range:
- AC 100 to 240V (50/60Hz)
- Dimensions:
- 96(W)X48(H)X80mm Depth
- Model Number:
- K3MA-F AC100-240V
- Power consumption:
- 6 VA max (max. load)
- External power supply:
- 12 VDC 40 mA
- Display range:
- -19999 to 99999
- A/D conversion method:
- Cycle measurement
- Comparative output response time:
- 750ms max
- Display method:
- 7-segment digital display
- Digits:
- Digits
- Net Weight:
- Approx. 300 g
Packaging Details - Unit Type:
- piece
- Package Weight:
- 1.500kg (3.31lb.)
- Package Size:
- 15cm x 8cm x 13cm (5.91in x 3.15in x 5.12in)
OMRON K3MA-F AC100-240V Digital panel meter,,rate meter, frequency meter This digital penel meter Using backlight double color LED (red/green), cathode LCD display, to achieve a high degree of visibility. With the function of comparing output , comparing preset value,,according to the comparison of the output t action, can change display colors, green to red(oppositely available ) Even thougth is far away from the device, also can by displaying a color change, can master operating condition of the device easily If don’t have the comparing output fuction, can choose the current color red or green , it depend on the the display purpose and usage of the production site Supply voltage | AC 100 to 240V (50/60Hz) | Operating voltage range | 85% to 110% of the rated power supply voltage | Power consumption | 6 VA max (max. load) | External power supply | 12 VDC 40 mA | Pulse measurement input (Input type) | NPN input/voltage pulse input | Pulse measurement input (No-voltage contact) | Input frequency range 30 Hz max. ON/OFF pulse width of 15 ms min. | Pulse measurement input (Voltage pulse) | Input frequency range 5kHz; ON/OFF pulse width of 90 us min. (Voltage level: ON voltage:4.5 to 30 V; OFF voltage :0 to 2 V; input impedance:10 k Ohm) | Pulse measurement input (Open collector) | Input frequency range 5kHz; ON/OFF pulse width of 90 us min. | Pulse measurement input (Accuracy) | +/- 0.1% +/- 1 digit | Connectable sensors | ON residual voltage: 2.5 V max. OFF leakage current: 0.1 mA max. Load current: Must have a switching capacity of 15 mA or higher. Must be able to properly switch load currents of 5 mA or less. | Display method | 7-segment digital display | Digits | 5 digits | Character height | 14.2 mm (green/red) | Zero suppress | Leading zeros are not displayed. | Decimal point display position | Selected with parameters | Filters function | Average processing | Display function | Display Color Selection, Display auto-return | Outputs function | Comparative Output Pattern, Startup Compensation Timer | Ambient temperature | Operating: -10 to +55 CEL Storage: -25 to +65 CEL (with no icing or condensation) | Ambient humidity | Operating: 25 to 85 %RH Storage: 25 to 85 %RH | Display range | -19999 to 99999 | A/D conversion method | Cycle measurement | Comparative output response time | 750ms max | Insulation resistance | 20 MOhm min.(at 500 VDC) between external terminals and case. Insulation provided between inputs, outputs and power supply. | Dielectric strength | 2,000 VAC 1min (between external terminals and case) | Noise immunity | +/- 1,500V at power supply terminals in normal or common mode(waveform with 1-ns rising edge and pulse width of 1us/100 ns) | Vibration resistance | Malfunction: Frequency: 10 to 55 Hz; Acceleration: 50m/s2 10 sweeps of 5 min each in X Y and Z directions | Shock resistance | Malfunction: 150 m/s2 3 times each on 3 axes 6 directions | Degree of protection | Front panel: NEMA4X for indoor use(equivalent to IP66) Rear case: IP20 Terminals: IP00 + finger protection(VDE0106/100) | Memory protection | EE-PROM(non-volatile memory) Number of rewrites: 100,000 | Safety standards | UL61010-1, CSA C22.2 No.61010-1-04, EN61010-1(IEC61010-1) | Applicable standard (EC Directive (EMC Directive)) | Standard No.: EN61326 EMI: EN61326 industrial applications Emission Enclosure: CISPR 11 Group1 Class A:CISPRL 16-1/-2 Emission AC mains: CISPR 11 Group1 Class A:CISPRL 16-1/-2 EMS: EN61326 industrial applications Immunity ESD: EN61000-4-2 (4 kV (contact) 8 kV (in air)) Immunity RF-interference: EN61000-4-3 (10 V/m sine wave amplitude modulation) Immunity Fast Transient Burst: EN61000-4-4 (2 kV (power line) 1 kV (I/O signal line)) Immunity Surge: EN61000-4-5 (1 kV with line(power line), 2 kV with ground(power line)) Immunity Conducted Disturbance: EN61000-4-6 (3 V (0.15 to 80 MHz)) Voltage Dips and interruptions immunity: EN61000-4-11 (0.5 cycle 0/180 degrees 100% (rated voltage)) | Net Weight | Approx. 300 g |
|
|
|
|
|