aHR0cDovL2ZyZWVzaGlwLmNvLmty Item specifics
- Power:
- Electric
- Structure:
- Single-stage Pump
- Brand Name:
- Warner Technology
- Pressure:
- Low Pressure
- Application:
- Submersible
- Standard or Nonstandard:
- Nonstandard
- Usage:
- Water
- Theory:
- Centrifugal Pump
- Model Number:
- DC50A-2450A
- Fuel:
- Electricity
- Driving method:
- Brushless, magnetic, 3phase
- Working Temperature Range:
- -10~100 Degrees Celsius
- Working condition:
- Submersible installation, can be continuously working
- Fluids:
- Water, oil, acid and alkali solution etc
- Rated voltage:
- 24Vdc
- Max rated current:
- 3.8A
- Max flow rate:
- 36L/Min(11GPM)
- Water proof class:
- IP68(can be submersible installed)
- Life span:
- >30,000hrs, can be continuously working
- Place of Origin:
- Guangdong, China (Mainland)
Packaging Details
- Unit Type:
- piece
- Package Weight:
- 0.700kg (1.54lb.)
- Package Size:
- 13cm x 8cm x 14cm (5.12in x 3.15in x 5.51in)
p style="margin: 0.0px;padding: 0.0px;text-align: center;color: #000000;line-height: 18.0px;font-family: verdana;">
Free shipping 5-24V Micro hot water circulation pump Lift 5M
Flow 3600LPH Brushless Motor Smart Speed Adjustable Submersible
TYPICAL FEATURES Compared with Common 2-phase Pump:
1)3-phase Brushless DC Design, seperation of control circuits and pump body;
2)can continuously pump 100C boiling water without stop;
3)Withstand Current and Voltage Impulse, Fit for freqent-switching use;
4)Rotor-block protection, for environment with articles;
Max Head 5m, Max Flow Rate 3600L/H
Long Life Span, More than 30,000hrs
Withstand high temp. as 100 degrees
Fit for continuously pumping hot water or other fluids
Low Noise, Completely Water Proof,speed adjustable
Features:
permanent magnetic rotor, maintenance-free, long life,speed adjustable
Can stand high temperature 100 degrees Celsuis, continuously pumping boiling water
Locked-rotor and reverse connection circuit protection, automatic overload protection
Soft-start with low in-rush current, suitable for direct solar panel connection
Small size, high efficiency, low consumption, low noise
Stator and circuit board sealed by epoxy resin, completely water proof
Sleeve and shaft with carbon fiber materials, better performance than ceramic and metal materials
Parameter can be customized for bulk demands, 24v pump’s Max head can be adjusted from 1m to 5m.
Specifications:
Sizes and weight:106mmx84mmx64mm; 600g
Dimension of Inlet and Outlet: 27mm
Power Saving: 86.4W
Low Noise: Less than 40dB
Wide Working Voltage Range: 5-24Vdc (24Vdc rated)
Max Static Head: 5m (16.5ft)
Max Flow Rate: 60L/Min (19G/Min)
Fluids: Water, oil, gasoline, acid and alkali solution, etc
Power Supply: can be battery, DC electric source or solar panel, etc
Super Long Life: >3years, can be continuously working, without maintenance
Water Proof Class: IP68 (Fit for submersible installation)
Parameters (The technical specification only for reference)
Package included:
1pcs x 24Vdc DC50A-2450A Micro Brushless DC Pump
This pump has a wide range of applications, motorcycle cooling and other vehicle cooling, landscaping and garden pumping, PC cooling system, humidifier, medical device,such as car cooling,and many other cooling and circulation system
How to Choose pump:
1. Make sure the working voltage, current, head and flow. The Max head means the static head. The pump can lift to the max heightwhen there is no flow. If you want special flow at special height, you must choose more higher head than the height you want to pump.
2. Make sure the dimension(threaded interface or not, the direction and diameter of outlet and inlet).
3. Working environment(temperature and medium).
4. Other functional requirements, such as time control, motion control, pressure control, flow control, and speed adjustment.
Note:
1. Working at rated voltage.The positive pole is brown wire, the negative pole is blue wire
2. This pump is centrifugal pump, it can\'t vent the air automatically, so it must be operated by submersible installation.(if outside water installation, you should make sure it is installed blow the liquid surface.
3. When blocking, long-running is not allowed.
4. Preventing any hard particles entering the pumps.
Cautions about usage
@@Working without liquid is prohibited, or it will damage or even burn the pump permanently for high temperature and abrasion.
@@Pumps can normally work when submersible installation or outside installation under the premise of a steady liquid flow into pumps.
@@Try to prevent hard articles entering pumps.
@@Pumps should work under specified temperature, higher temperature can result in magnet demagnetization and circuit performance degration.
@@Circuit polarity cannot be reversed and pumps cannot be directly connected with AC power supply without AC/DC transformer for they are DC pumps.
How to choose the most suitable pump
##Make sure of the working voltage, current, head and flow. Note that head means the maximum height that water can reach inside the external hose of outlet. If you want to get some flow at some height, you should retain a certain margin wtih these parameters. (refer to Head-Flow Curve graph)
##Make sure that the dimension can fit the application, such as the overall size of the pump, whether it is threaded interface, the direction and diameter of outlet and inlet, etc.
##Determine the working environment, such as working temperature, medium, etc.
##Take other requirements into consideration, such as time control, motion control, pressure control, flow control, and speed adjustable.