Packaging Details - Unit Type: Bag
- Package Weight: 1.9kg (4.19lb.)
- Package Size: 11cm x 11cm x 11cm (4.33in x 4.33in x 4.33in)
Packaging Details - Unit Type: Bag
- Package Weight: 1.9kg (4.19lb.)
- Package Size: 11cm x 11cm x 11cm (4.33in x 4.33in x 4.33in)
tyle="clear:both"> Double Clamps Earth Ground Resistance Tester Meter Soil Resistivity RK Wire Compensation Tester USB Features ¡Ü 2 pole method is used to measure DC resistance & AC resistance. ¡Ü 3 pole & 4 pole method is used to measure earth resistance. ¡Ü 4 pole method can be used to directly measuring soil resistivity. ¡Ü Current Clamp selection method is used to measuring earth resistance without breaking grounding connection. ¡Ü Double clamp without auxiliary electrode is used to fast measuring grounding resistance. ¡Ü Automatic frequency control(AFC) is automatically identified interference frequency and then selected the proper measurement frequency, so that reduced the affect of interference voltage. ¡Ü Automatically measuring the interference voltage and the leakage current. ¡Ü The limited value will be alarmed. ¡ÜAuto power off ¡ÜClock display ¡ÜDouble battery power supply and low battery indication ¡ÜData storage function and uploading to PC by USB2.0 interface. FUNCTION | MS2307 | 3 pole & 4 pole | voltage: AC20/48V | frequency: 94Hz, 105Hz, 111Hz, 128Hz. AFC | Resistance : 0.1¥Ø~30K¥Ø ±(5%rdg + 5dgt) | 3 pole & 4 pole with current clamp | voltage: AC20/48V | frequency: 94Hz, 105Hz, 111Hz, 128Hz. AFC | Resistance: 0.1¥Ø? 10K¥Ø ±(5%rdg + 5dgt) | Double clamp | voltage: AC48V | frequency: 94Hz, 105Hz, 111Hz, 128Hz. AFC | Resistance: 0.1¥Ø? 140¥Ø ±(10%rdg + 5dgt) | R~ 2 pole | voltage: AC20V | frequency: 94Hz, 105Hz, 111Hz, 128Hz. AFC | Resistance : 0.1¥Ø? 30k¥Ø ±(5%rdg + 5dgt) | R- 2/4 pole | --- | --- | Rk(Compliment measurement for Wire resistance ) | voltage: AC20/48V | frequency: 94Hz, 105Hz, 111Hz, 128Hz. AFC | Resistance : 0.1¥Ø? 29.99¥Ø ±(5%rdg + 5dgt) | Test Short Current | ¡Â200mA | Soil resistivity | voltage: AC20/48V | frequency: 94Hz, 105Hz, 111Hz, 128Hz. AFC | range: 1¥Øm-9999k¥Øm ±(5%rdg + 5dgt) | Measuring the disturb Voltage ,Current and Frequency | Voltage : ±1VDC~±50VDC,1VAC~50VAC. ±5%rdg +5dgt | Frequency: 16Hz-400Hz ±1%rdg.+2dgt | Current : 20mA-2A ±5%rdg+5dgt. | USB2.0 interface | ---- | Data Storage | Manually store 100 groups | Power supply | Lr6 ×6;voltage: 1.5V×6 | Recharge battery: NI-MH recharge Battery, 7.2V | AC Adapter:Input voltage : 100V~240V Frequency: 50Hz~60Hz Output voltage: 12VDC 3A | Display | LCD display, with Back light. Max 9999 | Dimension | 230(w)*125(h)*284(L)mm | Weight | Approx. 2.5Kg | -->
|