¸Þ´º Ç׸ñ:
P00: restore the default parameters (0 or 1, the default value of 0,0 for not recovering, 1 for the recovery)
P01: Operational amplifier gain (200 to 350 times, step 1, default 230)
P02: Operational amplifier offset voltage (0 ~ 250mV, step 2, the default value of 100, refers to the tip to keep the room temperature operational amplifier inherent output voltage, according to my measurement this voltage varies greatly with temperature, different magnification Not the same, the higher the magnification, if you do not measure, please keep the default value)
P03: thermocouple ¡É / mV data (30 ~ 50, step 1, the default value of 41, refers to the thermocouple need to temperature how much voltage was increased by 1mV, according to the type of thermocouple self-calculation, if you do not understand, please keep Defaults)
P04: temperature adjustment step (0,5,10 degrees optional, 0 can lock the soldering iron temperature)
P05: sleep time (how long don¡¯t not move into sleep) (0 ~ 60 minutes, step 1, 0 is to forbidden the sleep function)
P06: Shutdown time (0 ~ 180 minutes, 0 ~ 30 step 1,30 ~ 180 step 10, 0 is forbidden shutdown function)
P07: temperature correction (+20 degrees, step 1) (due to NTC resistance in the chassis, the soldering station heat will lead to the detection of NTC temperature higher than room temperature, resulting in high temperature compensation of the thermocouple, soldering iron temperature is not accurate,or other causes the temperature is not accurate.If you set the other parameters are correct value but the temperature is still high or low, you can use this parameter correction.For example, to detect the displayed soldering iron temperature is 20 degrees higher than the actual value of this parameter Set to 20)
P08: wake mode (0,1, 0 in the shutdown mode can be rotated the encoder and also can shake the handle to wake up, 1 can only rotate the encoder wake up (Note: press the encoder can not wake up, can only rotate) )
P09: temperature increase mode to increase the temperature to adjustable (20 degrees to 100 degrees adjustable, adjust the pace of 10 degrees)
P10: temperature to increase the duration to adjustable (adjustment range of 10 seconds to 250 seconds, adjust the step 5 seconds)
P11: Parameter setting mode Auto save parameter and return to heating mode Function to active time adjustable (range 4 seconds to 60 seconds)
Function&Advantage
1.Quick Heating & temp control accurate
2.Auto Sleep & Auto power off
3.Raise the handle to wake up the host
4.Get higher temp by pressing the encoder
input:AC 110V-240V Power supply:24V 4.5A
Temp:200degC-480degC Tin melting time:<8s