New process Meter fit FLUKE H787 loop calibrator T-RMS
TheH787 Process Meterwas the first tool to combine a loop calibrator with a fully-functional 1000V True RMS digital multimeter to give process technicians double the power in one tool.
A maintenance and calibration tool that will be at home in every instrumentation technician\'s tool box, the Fluke 787 Process Meter combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. The H787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.
Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you\'re tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power - the H787 Process Meter.
1. True Root Mean Square (TRUE RMS) measurement.
All measured value of AC voltage and AC current of this instrument are TRUE RMS, which is differential from low-end instruments that only measure the AC averages.
2. Manual/Auto Range
3. Percentage Range
4. Relative Value Measuring
6. Data Hold
7. Low power Detection
8. Backlight Control
9. This ProcessMeter can deliver steady, phase stepped or linear increasing current output to the loop with current 0-20 mA and/or 4-20 mA. It has three work models:
Current source model: enable the ProcessMeter to provide current to transmitters or passive circuits without supplying from external loops.
Analog current model: enable the ProcessMeter to adjust the current on external power (12-32 V) in the loop, which emulates a 2-wire transmitter.
Loop power model: enable the ProcessMeter to provide external equipment\'s power and measure the loop current.
General Characteristics
the maximum voltage between the measuring terminal and the earth is respectively 1000V DC, 700V AC. 1000V CAT III; class of pollution: 2
40000 counting, auto/manual range, basic sampling rate: 2.5 times/sec.
Indicator of over-range: -OL-.
When the total voltage of battery lower than about 6V, the symbol appears.
Rechargeable triple a battery 6X1.2V.
Work Temperature 0~30 (relative humidity 0~80%)
31~51 (relative humidity 0~50%)
Storage Temperature -20~60 (relative humidity <=80%)
Sea Level Height Work below 2000m
Storage below 10000m
Volume 200mm X 100mm X 40mm
Weight about 600g
Range and Accuracy
The accuracy of Ranges listed below are ensured under circumstances that the instrument under normal use within one year after calibration, and the basic condition is: work temperature 18-28, relative humidity lower than 80%. The representation of accuracy is: ± (reading value *% + lower order figures.
AC Voltage
Range | Resolution | Accuracy |
40Hz~1KHz | 1KHz~10KHz | 10KHz~20KHz |
400mV | 0.01mV | ±(0.8% +50) | ±(1.2% +50) | ±(2% +50) |
4V | 0.1mV | ±(0.8% +50) | ±(1.2% +50) | ±(2% +50) |
40V | 1mV | ±(0.8% +50) | ±(1.2% +50) | ±(2% +50) |
400V | 10mV | ±(0.8% +50) | ±(1.2% +50) | Not Specified |
700V | 0.1V | ±(0.8% +50) | Not Specified | Not Specified |
Note: above accuracies are ensured within 10%—100% of the full range.
Input impedance 10MΩ (standard), <100pF, AC coupling.
AC/DC conversion refers to RMS conversion.
Overvoltage Protection: 700V.
DC Voltage
Range | Resolution | Accuracy |
400mV | 0.01mV | ±(0.03% +5) |
4V | 0.1mV | ±(0.03% +5) |
40V | 1mV | ±(0.03% +5) |
400V | 10mV | ±(0.03% +5) |
1000V | 0.1V | ±(0.03% +5) |
Note: above accuracies are ensured within the full range.
Input Impedance10MΩ (standard), <100pF.
Overvoltage Protection: 1000V.
AC Current
Range | Resolution | Accuracy | Sample Resistance |
40Hz~1KHz | 1KHz~10KHz | 10KHz~20KHz |
40mA | 1μA | ±(0.8% +40) | ±(1.2% +40) | ±(2% +40) | 1Ω |
400mA | 10μA | ±(0.8% +40) | ±(1.2%+40) | ±(2% +40) |
10A | 1mA | ±(1.0% +40) | ±(1.5% +40) | Not Specified | 0.01Ω |
Note: above accuracies are ensured within 10%—100%of the full range.
In milliampere measuring, there is a 500mA quick blow fuse in ProcessMeter for protection; in ampere measuring, there is a 10A quick blow fuse in ProcessMeter for protection.
DC Current
Range | Resolution | Accuracy | Sample Resistance |
40mA | 1μA | ±(0.05% +6) | 1Ω |
400mA | 10μA | ±(0.05% +6) |
10A | 1mA | ±(0.1% +5) | 0.01Ω |
Note: above accuracies are ensured within the full range.
In milliampere measuring, there is a 500mA quick blow fuse in ProcessMeter for protection; in ampere measuring, there is a 12.5A quick blow fuse in ProcessMeter for protection.
Resistance
Range | Resolution | Accuracy |
400Ω | 0.01Ω | ±(0.1% +6) |
4KΩ | 0.1Ω | ±(0.1% +6) |
40KΩ | 1Ω | ±(0.1% +6) |
400KΩ | 10Ω | ±(0.1% +6) |
4MΩ | 100Ω | ±(0.2% +10) |
40MΩ | 1KΩ | ±(0.5% +50) |
Note: above accuracies are ensured within the full range.
Overload Protection: 250V, open circuit voltage: <1.25V.
Diode
Range | Resolution | Accuracy |
2.5V | 1mV | ±(1% +5) |
Note: the test current is about 1mA, the open circuit voltage is lower than 2.8V
Overload Protection: 250V.
Linear Frequency
Frequency Range | Voltage/Current Range | Sensitivity | Accuracy |
20Hz~50KHz Sine Wave | 4V | 0.1V | ±(0.05% +5) |
40V | 1V |
400V | 10V |
700V | 400V |
40 mA | 10mA |
400mA | 100mA |
Note: the accuracy may lose in lower voltage and/or lower frequency.
- protective yellow holster
- test leads
- alligator clips
- calibration report
- Portable bag
- Power supply
If you are not satisfied with your order, you can return/exchange in 14 days with full money refund (except shipping) as long as the products are in the original shape. Please DO contact us before you ship your order back, we will issue a RMA number and return address, the RMA number should appear on the package in order to get refund or exchange.
USA order will ship from our USA warehouse by USPS priority mail 3-4 business days. European customer: Shipping from our UK warehouse, UK customer can get 3-5 days service and other Europe customer get 4-9 days service with no duty tax. All other order will ship from our China warehouse by registered air mail, it takes around 7-14 business days to arrive, fast shipping is available by paying 25.00 more upgrade to express shipping with track number, thanks.
Your satisfaction is our highest priority, in case if you are not satisfied with your order or didn\'t get your order within reasonable time, please do contact us, we will try our best to help you in 1-2 business days. If you are satisfied with your order, please be kind to leave positive feedback for us, your valued suggestion is highly appreciated, we will send coupon or free gift upon your next purchase for any good suggestions we will take. If you have any questions and concerns, please feel free to e-mail to us or by phone (408)329-7985(408)329-7985or Fax (866) 571-5680. Thanks for interesting in our products and good luck.